Finsterwalder Umwelttechnik GmbH & Co. KG, Mailinger Weg 5, 83233 Bernau 
Tel.: +49 8051-965910-0, Fax: +49 8051-965910-20,
 


Waste Recovery by Anaerobic Digestion
AD plant Langage Farm UK

Process: Finsterwalder Umwelttechnik GmbH & Co.KG 

  1. Pre-treatment 
  2. Sanitation by double-tube heat exchanger (Pasteuriser)
  3. After-treatment of solid contaminants
  4. Digester discharge: Biogas, digestate and contaminants (sediment and scum)
  5. Power generation, heat production

Reference: AD plant Langage Farm (UK)

  • Performance: 713 kWel 
  • Feed stock: 12,000 t/a food waste and expired, packaged foods, 3,000 t/a cattle manure, 500 t/a dairy waste
  • Commissioning in March 2011

FITEC Services:

  • Prearrangement
  • Development design
  • Approval planning
  • Detailed design
  • Commissioning

FITEC Components:

  • Double tube heat exchanger
  • Floor scrapers
  • Plant control system

Double-tube heat exchanger with holding tanks

AD plant Langage Farm

Central feeding pump

Hammer mill with belt conveyor

 
© Finsterwalder Umwelttechnik - www.fitec.com